We and selected third parties use cookies or similar technologies for technical purposes and, with your consent, also for other purposes as specified in the cookie policy.
The 90OPV-8R overvoltage limiter effectively protects signal line carrying away the stroke current to the ground, due to above provides adequate overvoltage protection for electronic devices. Our statistics collected from many years of service show that about 25 percent of damages of electronic equipment was caused by overvoltages.
The 90OPV-8R does not affect signal quality and is a passive device, no supplying is required.
ATTENTION! Before installation please read the following instructions: Any installation work cannot be led during thunderstorm. The 90OPV-8R requires good quality grounding installation. The limiter should be placed as near as possible to the protected device. The 90OPV-8R is not symmetrical and the protected devices must be connected to the "PROTECTED DEVICE" BNC output sockets. The "LINE" input BNC sockets must be connected to the transmitting lines, which may surge.
https://www.liberotech.com/ww/video-overvoltage-limiter-8ch-bnc-pcb-board.html90-OPV8/RVideo Overvoltage limiter 8CH BNC - PCB board<div>
The <strong>90OPV-8R</strong> overvoltage limiter effectively protects signal line carrying away the stroke current to the ground, due to above provides adequate overvoltage protection for electronic devices. Our statistics collected from many years of service show that about 25 percent of damages of electronic equipment was caused by overvoltages.</div>
<div>
</div>
<div>
The <strong>90OPV-8R</strong> does not affect signal quality and is a passive device, no supplying is required.</div>
<div>
</div>
<div>
ATTENTION! Before installation please read the following instructions: Any installation work cannot be led during thunderstorm. The <strong>90OPV-8R</strong> requires good quality grounding installation. The limiter should be placed as near as possible to the protected device. The <strong>90OPV-8R</strong> is not symmetrical and the protected devices must be connected to the "PROTECTED DEVICE" BNC output sockets. The "LINE" input BNC sockets must be connected to the transmitting lines, which may surge. </div>https://www.liberotech.com/media/catalog/product/_/9/_9_0_90opv-8r.jpg38.68instock38.6838.6800NO BRAND000https://www.liberotech.com/media/catalog/product/_/9/_9_0_90opv-8r.jpg/Networking/Networking/Racks16878578730001068900
Buy everything you want in 3 interest-free installments with Scalapay